Arc Fault Detection Device (AFDD), also known as an Arc Fault Circuit Interrupter (AFCI), is an advanced safety device designed to detect dangerous arc faults that standard circuit breakers cannot recognize. These arc faults, often caused by damaged wires, loose connections, or aging insulation, are one of the leading causes of electrical fires in homes and buildings.

Timelec’s arc fault detection devices actively monitor electrical circuits and instantly disconnect power when abnormal arcing is detected, preventing ignition before it can lead to fire. Unlike traditional protection devices such as MCBs or RCDs, AFDDs are specifically engineered to sense high-frequency arc signatures that indicate a real threat.

Timelec AFDD support type A, type AC, could widely used in AC circuit and DC(direct current), rating current support 25A, 40A, tripping curve B and C curve are available.

TMA3-40 B40

TMA3-40

B40 Type AC

Curve B 40A
AFDD + RCBO integrated protection

Get a Quote
TMA1-40 C25

TMA1-40

C25 Type A

Curve C 25A
Suitable for AC and DC systems

Get a Quote
TMA3-40 C25 A

TMA3-40

C25 Type A

Curve C 25A
For residential and commercial use

Get a Quote
TMA3-40 C25 AC

TMA3-40

C25 Type AC

Curve C 25A
Ideal for home distribution

Get a Quote

Arc Fault Detection Devices (AFDDs) or AFCIs,  are advanced safety components that actively detect and eliminate hidden electrical arc faults before they can start a fire. Unlike traditional circuit breakers, which only respond to overcurrent or leakage, AFDDs are specifically designed to identify high-frequency arc signals caused by damaged wires, loose connections, or aging insulation.

When an arc fault occurs—such as a spark in a damaged cable—

  • Detecting Faults: AFDDs monitor electrical currents and identify abnormal arc faults caused by damaged wires or loose connections.

  • Analyzing Patterns: They analyze the electrical waveforms to distinguish harmful fault arcs from normal activity. These  fault arcs generate extreme heat, even can cause arc flash , which can ignite nearby flammable materials.

  • Warning Signals: If a dangerous arc is detected, the device’s indicator light flashes to alert users.

  • Immediate Power Cut-Off: If the fault arc persists or reaches a critical level, the AFDD shuts off power, stopping the arc before it can start a fire.

While the arc fault could happen in many situation,  like aging or frayed wiring, loose connections in outlets, switches, or electrical panels, cables that are crushed, rodent damage where animals chew through insulation and moisture intrusion.

At Timelec, our AFDDs are built with precise detection technology and high-performance components to ensure fast and reliable response. By integrating our AFDDs into your  project home or commercial power system, you’re taking a crucial step in protecting both lives and property against one of the most common causes of electrical fires.

Whether for new installations or retrofit upgrades, Timelec’s arc fault detection devices offer an intelligent, proactive layer of fire prevention—meeting modern safety expectations with ease.

An Arc Fault Detection Device (AFDD) prevents electrical fires by detecting hazardous arcs, which could lead to extremely high temperatures. And AFDD cut off power instantly. Required by BS 7671:2018+A2:2022 in high-risk areas, AFDDs offer protection beyond traditional circuit breakers(like MCB, RCD or RCBO), making them essential for safety. Installing arc fault detection devices(AFDD) reduces fire risks and safeguards lives.

Installing an Arc Fault Detection Device (AFDD) requires careful adherence to electrical safety standards. First, turn off the power supply and confirm the circuit is fully de-energized. AFDDs are typically installed within the distribution panel alongside circuit breakers, so selecting the right model that fits the system’s voltage and load requirements is crucial. Connect the AFDD in series with the circuit, ensuring proper alignment of live, neutral, and ground wires, and securely mount it in the panel. Once installed, restore power and test the device to verify its functionality by simulating an arc fault condition. Compliance with National Electrical Code (NEC) standards and local regulations must be confirmed, and a final inspection by a licensed electrician is recommended to ensure safety and proper operation. Installing arc fault detection devices enhances electrical safety by significantly reducing fire risks and protecting lives.

 

Timelec Arc fault s are engineered with precision and reliability in mind. Our arc fault detection devices are built to detect even the smallest electrical arcs caused by damaged cables, loose connections, or aging insulation—long before they turn into fires.

Arc fault detection device TMA3-40 C25 type A
PV Solar System
AFDD in household
House
Commercial Lighting System
Commercial Buildings

Contact us for a customized estimate on our expert electrical services.

Blank Form (#3)
Timelec brand logo
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.