RCBO Manufacturer

RCBO

IEC 61009-1 · Types: AC / A / F / B · Certifications: CB, CE, S, UKCA

TIMELEC integrates residual current and overcurrent protection into one compact RCBO device, providing safe, reliable and space-saving solutions for residential, commercial and industrial distribution panels.

As a professional RCBO manufacturer, TIMELEC combines MCB and RCD functions through an internal zero-sequence current transformer, enabling continuous comparison of live and neutral currents with overload and short-circuit protection.

  • Certifications: CB, CE, S, UKCA
  • Pole: 1P+N / 2P / 3P / 3P+N / 4P
  • Rated current: 6 A–63 A
  • Breaking capacity: 6 kA / 10 kA
  • Mounting: 35 mm DIN rail
Send Inquiry
TIMELEC RCBO manufacturer TMRO7-40 residual current breaker with overcurrent protection

TIMELEC RCBO manufacturer — TMRO7 residual current breakers with overcurrent protection. IEC 61009-1, Type AC/A/F/B, ELE/ELM, 6–40A for residential and commercial panels. CB/CE/S.mark. Factory OEM/ODM available worldwide.

RCBO Product Range

Timelec manufactures low-voltage electrical protection products for global OEM and ODM customers.

RCBO Breakers TMRO6-63 4P High Current

RCBO Breakers TMRO6-63 4P High Current

  • Rated current: up to 63A
  • Poles: 4P
  • 3 phase RCBO ready
View Product Details
RCBO Breakers TMRO6-63 6KA 2P

RCBO Breakers TMRO6-63 6KA 2P

  • Breaking capacity: 6kA
  • Poles: 2P
  • RCBO circuit breaker
View Product Details
RCBO Circuit Breaker TMRO10-63 63a 6KA 4P

RCBO Circuit Breaker TMRO10-63 63A 6kA 4P

  • Rated current: 63A
  • Breaking capacity: 6kA
  • Poles: 4P
View Product Details
RCBO TMRO1-50 C32 30MA TYPEA 10KA 1P+N

RCBO TMRO1-50 C32 30mA Type A 10kA 1P+N

  • Rated current: 32A
  • IΔn: 30mA Type A
  • 32A RCBO / 1P+N
View Product Details
RCBO TMRO100-63 C63 10KA

RCBO TMRO100-63 C63 10kA

  • Rated current: 63A
  • Breaking capacity: 10kA
  • RCBO circuit breaker
View Product Details
TMRO1-50 1P+N 50A 6KA TypeA RCBO

TMRO1-50 1P+N 50A 6kA Type A RCBO

  • Rated current: 50A
  • Breaking capacity: 6kA
  • Type A / 1P+N
View Product Details

RCBO Applications

  • Residential buildings
  • Commercial office buildings
  • Hotels
  • Hospitals
  • Schools
  • Data centers
  • Industrial control panels
  • Electric-vehicle (EV) charging systems
  • Solar PV distribution boxes

As electrical-safety regulations continue to evolve, RCBOs are increasingly replacing traditional protection arrangements in many new construction projects.

Comprehensive Leakage Protection Types

TIMELEC provides a full spectrum of RCBOs classified by sensitivity to different fault current waveforms for residential, commercial and industrial projects.

Type AC RCBO

Ideal for standard electrical installations subject to sinusoidal AC fault currents.

Type A RCBO

Designed for circuits with electronic rectifiers, handling both AC and pulsating DC fault currents.

Type F RCBO

Recommended for frequency converters, inverters and applications with residual pulsating DC currents.

Type B RCBO

Suitable for complex electronics, PV systems and installations with smooth DC leakage components.

Tell us your load type and market standard — we will recommend the right RCBO configuration.

Send Inquiry

RCBO Selection for Wide Loads

TIMELEC provides a comprehensive matrix of sensitivities and tripping curves to match different electrical environments, from residential lighting to commercial inductive loads.

Residual Operating Current (IΔn)

  • 10mA & 30mA (High Sensitivity): Fast reaction for direct-contact protection in bathrooms, sockets and residential circuits.
  • 100mA & 300mA (Low Sensitivity): Equipment protection and fire-hazard prevention in commercial and industrial distribution lines.

Common Magnetic Tripping Curves

B CurveTrips between 3–5In. Ideal for resistive loads, heaters and long cable runs with minimal inrush current.
C CurveTrips between 5–10In. Standard choice for commercial lighting, small motors and general applications.

Why Choose TIMELEC as Your RCBO Manufacturer?

Partner with trusted RCBO manufacturers and suppliers to obtain reliable residual current circuit breakers conforming to the IEC 61009-1 standard, featuring overcurrent protection and equipped with ELE/ELM mechanisms and AC/A/F/B type options for various markets.

Higher Safety

The function of RCBO is to provide precise and rapid protection against three core risks in low-voltage power distribution: electric shock (leakage), overheating (overload), and instantaneous high current (short circuit) through an integrated device. Suitable for AC 50Hz circuits with rated voltage up to 240V and rated current up to 40A, used for detecting AC leakage current and pulsating DC leakage current.

Faster Fault Finding

The RCBO combines the functions of a miniature circuit breaker and a residual current device. It contains an internal zero-sequence current transformer that provides independent circuit protection by passing through both the live and neutral wires.

A More Compact Distribution Board

A single RCBO combines the functions of an MCB and an RCD, helping create a more compact and organized distribution-board layout.

Lower Overall Installation Cost

By integrating earth-leakage, overload, and short-circuit protection, RCBOs can reduce the number of separate RCDs/RCCBs, MCBs, and connection accessories required, while simplifying wiring and installation.

RCBO Technical Data

Number of Poles1P+N, switched neutral pole
Rated voltage230/240V ~
Insulation voltage (Ui)500 VAC
Rated frequency50/60HZ
Rating current (In)6, 10, 13, 16, 20, 25, 32, 40A
Rated residual operating current (IΔn)10mA/30mA/100mA/300 mA
Rated residual operating current typeAC type & A type & F type & B type
Rated nominal breaking capacity (Icn)6KA
Degree of protectionIP20
StandardIEC/ EN 61009-1
IEC/EN 62423
EnclosureNylon PA6 or Nylon PA66
Connection plateCopper
Silver contact pointSilver graphite
LatchPPA
LeverDSM PPS

RCBO Full Form: Residual Current Operated Circuit Breaker

RCBOs combine residual current protection and overcurrent protection in one DIN-rail device for modern low-voltage distribution systems.

What is an RCBO?

An RCBO combines the functions of a residual current device (RCD) and a miniature circuit breaker (MCB). This dual functionality provides comprehensive protection against both earth leakage and overcurrent faults in a single compact module.

TIMELEC RCBOs are engineered for IEC 61009-1 compliance with ELE/ELM mechanisms and Type AC / A / F / B options for different markets.

How does an RCBO work?

The device uses a zero-sequence current transformer to compare live and neutral currents. When an imbalance caused by leakage is detected, the RCBO trips quickly to reduce electric shock risk.

At the same time, built-in overcurrent protection responds to overloads and short circuits, helping prevent overheating and fire hazards in distribution circuits.

RCBO vs. RCCB: Feature Comparison

FeatureRCBORCCB
Residual current protectionYesYes
Overcurrent protectionYesNo
Device typeSingle compact unitRequires separate MCB
ApplicationsIndividual circuits (lighting, sockets, appliances)Broader circuit groups in distribution boards
Installation benefitMore compact panel layoutLower unit cost, more components needed

RCBO Manufacturer FAQ

Common questions about TIMELEC residual current breakers with overcurrent protection.

What is an RCBO used for?

Suitable for AC 50Hz circuits with rated voltage up to 240V and rated current up to 40A, used for detecting AC leakage current and pulsating DC leakage current.

What do 30mA, 100mA and 300mA RCBO ratings mean?

Because each RCBO provides independent circuit protection, it does not affect other circuits and can be selected for different protection levels:

  • 30mA: Protection against electric shock (residential, office, school, etc.)
  • 100mA: Equipment protection, fire protection
  • 300mA: Line fire protection, industrial power distribution systems
Which standard do TIMELEC RCBO products comply with?

TIMELEC RCBO devices are designed in accordance with IEC 61009-1 and are available with CB, CE, S and UKCA certification support for export markets.

What is the difference between Type AC, A, F and B RCBO?

RCBO types relate to the waveform and frequency of residual fault current. Type AC, A, F and B options are selected according to national standards and load characteristics in different countries and applications.

Which is better, RCBO or MCB?

An RCBO provides both overcurrent and earth-leakage protection in one device. If only an MCB is used, a separate RCCB is required for leakage protection. RCBOs also isolate only the affected circuit, keeping other circuits energized.

Do you offer OEM / ODM as an RCBO manufacturer?

Yes. TIMELEC supports OEM/ODM customization for RCBO products, including ratings, Type AC/A/F/B options, packaging and private-label branding for distributors and panel builders.

Inquiry Now

Tell us about your RCBO requirements and our sales team will contact you with product and configuration support.

Blank Form (#3)
Timelec brand logo
Privacy Overview

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.